published on Monday, Nov 16, 2026 by e-breuninger
published on Monday, Nov 16, 2026 by e-breuninger
A cable between two sets of terminations (dcim.cable): interfaces, front and rear ports, console and power ports, power feeds or circuit terminations.
From the official documentation:
All connections between device components in NetBox are represented using cables. A cable represents a direct physical connection between two sets of endpoints (A and B), such as a console port and a patch panel port, or between two network interfaces.
Example Usage
import * as pulumi from "@pulumi/pulumi";
import * as netbox from "@pulumi/netbox";
const test = netbox.getCable({
id: 123,
});
import pulumi
import pulumi_netbox as netbox
test = netbox.get_cable(id=123)
package main
import (
"github.com/pulumi/pulumi-terraform-provider/sdks/go/netbox/v6/netbox"
"github.com/pulumi/pulumi/sdk/v3/go/pulumi"
)
func main() {
pulumi.Run(func(ctx *pulumi.Context) error {
_, err := netbox.LookupCable(ctx, &netbox.LookupCableArgs{
Id: pulumi.Float64Ref(123),
}, nil)
if err != nil {
return err
}
return nil
})
}
using System.Collections.Generic;
using System.Linq;
using Pulumi;
using Netbox = Pulumi.Netbox;
return await Deployment.RunAsync(() =>
{
var test = Netbox.GetCable.Invoke(new()
{
Id = 123,
});
});
package generated_program;
import com.pulumi.Context;
import com.pulumi.Pulumi;
import com.pulumi.core.Output;
import com.pulumi.netbox.NetboxFunctions;
import com.pulumi.netbox.inputs.GetCableArgs;
import java.util.List;
import java.util.ArrayList;
import java.util.Map;
import java.io.File;
import java.nio.file.Files;
import java.nio.file.Paths;
public class App {
public static void main(String[] args) {
Pulumi.run(App::stack);
}
public static void stack(Context ctx) {
final var test = NetboxFunctions.getCable(GetCableArgs.builder()
.id(123)
.build());
}
}
variables:
test:
fn::invoke:
function: netbox:getCable
arguments:
id: 123
Example coming soon!
Using getCable
Two invocation forms are available. The direct form accepts plain arguments and either blocks until the result value is available, or returns a Promise-wrapped result. The output form accepts Input-wrapped arguments and returns an Output-wrapped result.
function getCable(args: GetCableArgs, opts?: InvokeOptions): Promise<GetCableResult>
function getCableOutput(args: GetCableOutputArgs, opts?: InvokeOutputOptions): Output<GetCableResult>def get_cable(bundle_id: Optional[float] = None,
bundle_name: Optional[str] = None,
circuittermination_id: Optional[float] = None,
color: Optional[str] = None,
consoleport_id: Optional[float] = None,
consoleserverport_id: Optional[float] = None,
created: Optional[str] = None,
custom_field_filters: Optional[Mapping[str, str]] = None,
description: Optional[str] = None,
device_id: Optional[float] = None,
device_name: Optional[str] = None,
frontport_id: Optional[float] = None,
id: Optional[float] = None,
interface_id: Optional[float] = None,
label: Optional[str] = None,
last_updated: Optional[str] = None,
length: Optional[float] = None,
length_unit: Optional[str] = None,
location_id: Optional[float] = None,
location_slug: Optional[str] = None,
owner_group_id: Optional[float] = None,
owner_group_name: Optional[str] = None,
owner_id: Optional[float] = None,
owner_name: Optional[str] = None,
powerfeed_id: Optional[float] = None,
poweroutlet_id: Optional[float] = None,
powerport_id: Optional[float] = None,
profile: Optional[str] = None,
q: Optional[str] = None,
rack_id: Optional[float] = None,
rack_name: Optional[str] = None,
rearport_id: Optional[float] = None,
site_id: Optional[float] = None,
site_slug: Optional[str] = None,
status: Optional[str] = None,
tag_id: Optional[float] = None,
tag_slug: Optional[str] = None,
tenant_group_id: Optional[str] = None,
tenant_group_slug: Optional[str] = None,
tenant_id: Optional[float] = None,
tenant_slug: Optional[str] = None,
termination_a_id: Optional[float] = None,
termination_a_type: Optional[str] = None,
termination_b_id: Optional[float] = None,
termination_b_type: Optional[str] = None,
type: Optional[str] = None,
unterminated: Optional[bool] = None,
opts: Optional[InvokeOptions] = None) -> GetCableResult
def get_cable_output(bundle_id: pulumi.Input[Optional[float]] = None,
bundle_name: pulumi.Input[Optional[str]] = None,
circuittermination_id: pulumi.Input[Optional[float]] = None,
color: pulumi.Input[Optional[str]] = None,
consoleport_id: pulumi.Input[Optional[float]] = None,
consoleserverport_id: pulumi.Input[Optional[float]] = None,
created: pulumi.Input[Optional[str]] = None,
custom_field_filters: pulumi.Input[Optional[Mapping[str, pulumi.Input[str]]]] = None,
description: pulumi.Input[Optional[str]] = None,
device_id: pulumi.Input[Optional[float]] = None,
device_name: pulumi.Input[Optional[str]] = None,
frontport_id: pulumi.Input[Optional[float]] = None,
id: pulumi.Input[Optional[float]] = None,
interface_id: pulumi.Input[Optional[float]] = None,
label: pulumi.Input[Optional[str]] = None,
last_updated: pulumi.Input[Optional[str]] = None,
length: pulumi.Input[Optional[float]] = None,
length_unit: pulumi.Input[Optional[str]] = None,
location_id: pulumi.Input[Optional[float]] = None,
location_slug: pulumi.Input[Optional[str]] = None,
owner_group_id: pulumi.Input[Optional[float]] = None,
owner_group_name: pulumi.Input[Optional[str]] = None,
owner_id: pulumi.Input[Optional[float]] = None,
owner_name: pulumi.Input[Optional[str]] = None,
powerfeed_id: pulumi.Input[Optional[float]] = None,
poweroutlet_id: pulumi.Input[Optional[float]] = None,
powerport_id: pulumi.Input[Optional[float]] = None,
profile: pulumi.Input[Optional[str]] = None,
q: pulumi.Input[Optional[str]] = None,
rack_id: pulumi.Input[Optional[float]] = None,
rack_name: pulumi.Input[Optional[str]] = None,
rearport_id: pulumi.Input[Optional[float]] = None,
site_id: pulumi.Input[Optional[float]] = None,
site_slug: pulumi.Input[Optional[str]] = None,
status: pulumi.Input[Optional[str]] = None,
tag_id: pulumi.Input[Optional[float]] = None,
tag_slug: pulumi.Input[Optional[str]] = None,
tenant_group_id: pulumi.Input[Optional[str]] = None,
tenant_group_slug: pulumi.Input[Optional[str]] = None,
tenant_id: pulumi.Input[Optional[float]] = None,
tenant_slug: pulumi.Input[Optional[str]] = None,
termination_a_id: pulumi.Input[Optional[float]] = None,
termination_a_type: pulumi.Input[Optional[str]] = None,
termination_b_id: pulumi.Input[Optional[float]] = None,
termination_b_type: pulumi.Input[Optional[str]] = None,
type: pulumi.Input[Optional[str]] = None,
unterminated: pulumi.Input[Optional[bool]] = None,
opts: Optional[InvokeOutputOptions] = None) -> Output[GetCableResult]func LookupCable(ctx *Context, args *LookupCableArgs, opts ...InvokeOption) (*LookupCableResult, error)
func LookupCableOutput(ctx *Context, args *LookupCableOutputArgs, opts ...InvokeOption) LookupCableResultOutput> Note: This function is named LookupCable in the Go SDK.
public static class GetCable
{
public static Task<GetCableResult> InvokeAsync(GetCableArgs args, InvokeOptions? opts = null)
public static Output<GetCableResult> Invoke(GetCableInvokeArgs args, InvokeOptions? opts = null)
public static Output<GetCableResult> Invoke(GetCableInvokeArgs args, InvokeOutputOptions opts)
}public static CompletableFuture<GetCableResult> getCable(GetCableArgs args, InvokeOptions options)
public static Output<GetCableResult> getCable(GetCableArgs args, InvokeOptions options)
public static Output<GetCableResult> getCable(GetCableArgs args, InvokeOutputOptions options)
fn::invoke:
function: netbox:index/getCable:getCable
arguments:
# arguments dictionarydata "netbox_get_cable" "name" {
# arguments
}The following arguments are supported:
- Bundle
Id double - Id of the cable bundle.
- Bundle
Name string - Name of the cable bundle.
- Circuittermination
Id double - Id of the circuittermination.
- Color string
- Color to match.
- Consoleport
Id double - Id of the consoleport.
- Consoleserverport
Id double - Id of the consoleserverport.
- Created string
- Custom
Field Dictionary<string, string>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Description string
- Device
Id double - Id of a device the cable is connected to.
- Device
Name string - Name of a device the cable is connected to.
- Frontport
Id double - Id of the frontport.
- Id double
- NetBox id.
- Interface
Id double - Id of the interface.
- Label string
- Physical label.
- Last
Updated string - Length double
- Cable length; requires length_unit.
- Length
Unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- Location
Id double - Id of the location a termination of the cable is in.
- Location
Slug string - Slug of the location.
- Owner
Group doubleId - Id of the owner group.
- Owner
Group stringName - Name of the owner group.
- Owner
Id double - Id of the owner the object is assigned to.
- Owner
Name string - Name of the owner.
- Powerfeed
Id double - Id of the powerfeed.
- Poweroutlet
Id double - Id of the poweroutlet.
- Powerport
Id double - Id of the powerport.
- Profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Rack
Id double - Id of the rack a termination of the cable is in.
- Rack
Name string - Name of the rack.
- Rearport
Id double - Id of the rearport.
- Site
Id double - Id of the site a termination of the cable is in.
- Site
Slug string - Slug of the site a termination of the cable is in.
- Status string
- Cable status. One of: connected, planned, decommissioning.
- Tag
Id double - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- Tenant
Group stringId - Id of the tenant group.
- Tenant
Group stringSlug - Slug of the tenant group.
- Tenant
Id double - Id of the tenant.
- Tenant
Slug string - Slug of the tenant.
- Termination
AId double - Id of the termination a.
- Termination
AType string - Termination a type to match.
- Termination
BId double - Id of the termination b.
- Termination
BType string - Termination b type to match.
- Type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- Unterminated bool
- Unterminated.
- Bundle
Id float64 - Id of the cable bundle.
- Bundle
Name string - Name of the cable bundle.
- Circuittermination
Id float64 - Id of the circuittermination.
- Color string
- Color to match.
- Consoleport
Id float64 - Id of the consoleport.
- Consoleserverport
Id float64 - Id of the consoleserverport.
- Created string
- Custom
Field map[string]stringFilters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Description string
- Device
Id float64 - Id of a device the cable is connected to.
- Device
Name string - Name of a device the cable is connected to.
- Frontport
Id float64 - Id of the frontport.
- Id float64
- NetBox id.
- Interface
Id float64 - Id of the interface.
- Label string
- Physical label.
- Last
Updated string - Length float64
- Cable length; requires length_unit.
- Length
Unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- Location
Id float64 - Id of the location a termination of the cable is in.
- Location
Slug string - Slug of the location.
- Owner
Group float64Id - Id of the owner group.
- Owner
Group stringName - Name of the owner group.
- Owner
Id float64 - Id of the owner the object is assigned to.
- Owner
Name string - Name of the owner.
- Powerfeed
Id float64 - Id of the powerfeed.
- Poweroutlet
Id float64 - Id of the poweroutlet.
- Powerport
Id float64 - Id of the powerport.
- Profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Rack
Id float64 - Id of the rack a termination of the cable is in.
- Rack
Name string - Name of the rack.
- Rearport
Id float64 - Id of the rearport.
- Site
Id float64 - Id of the site a termination of the cable is in.
- Site
Slug string - Slug of the site a termination of the cable is in.
- Status string
- Cable status. One of: connected, planned, decommissioning.
- Tag
Id float64 - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- Tenant
Group stringId - Id of the tenant group.
- Tenant
Group stringSlug - Slug of the tenant group.
- Tenant
Id float64 - Id of the tenant.
- Tenant
Slug string - Slug of the tenant.
- Termination
AId float64 - Id of the termination a.
- Termination
AType string - Termination a type to match.
- Termination
BId float64 - Id of the termination b.
- Termination
BType string - Termination b type to match.
- Type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- Unterminated bool
- Unterminated.
- bundle_
id number - Id of the cable bundle.
- bundle_
name string - Name of the cable bundle.
- circuittermination_
id number - Id of the circuittermination.
- color string
- Color to match.
- consoleport_
id number - Id of the consoleport.
- consoleserverport_
id number - Id of the consoleserverport.
- created string
- custom_
field_ map(string)filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description string
- device_
id number - Id of a device the cable is connected to.
- device_
name string - Name of a device the cable is connected to.
- frontport_
id number - Id of the frontport.
- id number
- NetBox id.
- interface_
id number - Id of the interface.
- label string
- Physical label.
- last_
updated string - length number
- Cable length; requires length_unit.
- length_
unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- location_
id number - Id of the location a termination of the cable is in.
- location_
slug string - Slug of the location.
- owner_
group_ numberid - Id of the owner group.
- owner_
group_ stringname - Name of the owner group.
- owner_
id number - Id of the owner the object is assigned to.
- owner_
name string - Name of the owner.
- powerfeed_
id number - Id of the powerfeed.
- poweroutlet_
id number - Id of the poweroutlet.
- powerport_
id number - Id of the powerport.
- profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- rack_
id number - Id of the rack a termination of the cable is in.
- rack_
name string - Name of the rack.
- rearport_
id number - Id of the rearport.
- site_
id number - Id of the site a termination of the cable is in.
- site_
slug string - Slug of the site a termination of the cable is in.
- status string
- Cable status. One of: connected, planned, decommissioning.
- tag_
id number - Id of a tag the object carries.
- tag_
slug string - Slug of a tag the object carries.
- tenant_
group_ stringid - Id of the tenant group.
- tenant_
group_ stringslug - Slug of the tenant group.
- tenant_
id number - Id of the tenant.
- tenant_
slug string - Slug of the tenant.
- termination_
a_ numberid - Id of the termination a.
- termination_
a_ stringtype - Termination a type to match.
- termination_
b_ numberid - Id of the termination b.
- termination_
b_ stringtype - Termination b type to match.
- type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- unterminated bool
- Unterminated.
- bundle
Id Double - Id of the cable bundle.
- bundle
Name String - Name of the cable bundle.
- circuittermination
Id Double - Id of the circuittermination.
- color String
- Color to match.
- consoleport
Id Double - Id of the consoleport.
- consoleserverport
Id Double - Id of the consoleserverport.
- created String
- custom
Field Map<String,String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description String
- device
Id Double - Id of a device the cable is connected to.
- device
Name String - Name of a device the cable is connected to.
- frontport
Id Double - Id of the frontport.
- id Double
- NetBox id.
- interface
Id Double - Id of the interface.
- label String
- Physical label.
- last
Updated String - length Double
- Cable length; requires length_unit.
- length
Unit String - Unit of length. One of: km, m, cm, mi, ft, in.
- location
Id Double - Id of the location a termination of the cable is in.
- location
Slug String - Slug of the location.
- owner
Group DoubleId - Id of the owner group.
- owner
Group StringName - Name of the owner group.
- owner
Id Double - Id of the owner the object is assigned to.
- owner
Name String - Name of the owner.
- powerfeed
Id Double - Id of the powerfeed.
- poweroutlet
Id Double - Id of the poweroutlet.
- powerport
Id Double - Id of the powerport.
- profile String
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- rack
Id Double - Id of the rack a termination of the cable is in.
- rack
Name String - Name of the rack.
- rearport
Id Double - Id of the rearport.
- site
Id Double - Id of the site a termination of the cable is in.
- site
Slug String - Slug of the site a termination of the cable is in.
- status String
- Cable status. One of: connected, planned, decommissioning.
- tag
Id Double - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
- tenant
Group StringId - Id of the tenant group.
- tenant
Group StringSlug - Slug of the tenant group.
- tenant
Id Double - Id of the tenant.
- tenant
Slug String - Slug of the tenant.
- termination
AId Double - Id of the termination a.
- termination
AType String - Termination a type to match.
- termination
BId Double - Id of the termination b.
- termination
BType String - Termination b type to match.
- type String
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- unterminated Boolean
- Unterminated.
- bundle
Id number - Id of the cable bundle.
- bundle
Name string - Name of the cable bundle.
- circuittermination
Id number - Id of the circuittermination.
- color string
- Color to match.
- consoleport
Id number - Id of the consoleport.
- consoleserverport
Id number - Id of the consoleserverport.
- created string
- custom
Field {[key: string]: string}Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description string
- device
Id number - Id of a device the cable is connected to.
- device
Name string - Name of a device the cable is connected to.
- frontport
Id number - Id of the frontport.
- id number
- NetBox id.
- interface
Id number - Id of the interface.
- label string
- Physical label.
- last
Updated string - length number
- Cable length; requires length_unit.
- length
Unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- location
Id number - Id of the location a termination of the cable is in.
- location
Slug string - Slug of the location.
- owner
Group numberId - Id of the owner group.
- owner
Group stringName - Name of the owner group.
- owner
Id number - Id of the owner the object is assigned to.
- owner
Name string - Name of the owner.
- powerfeed
Id number - Id of the powerfeed.
- poweroutlet
Id number - Id of the poweroutlet.
- powerport
Id number - Id of the powerport.
- profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- rack
Id number - Id of the rack a termination of the cable is in.
- rack
Name string - Name of the rack.
- rearport
Id number - Id of the rearport.
- site
Id number - Id of the site a termination of the cable is in.
- site
Slug string - Slug of the site a termination of the cable is in.
- status string
- Cable status. One of: connected, planned, decommissioning.
- tag
Id number - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- tenant
Group stringId - Id of the tenant group.
- tenant
Group stringSlug - Slug of the tenant group.
- tenant
Id number - Id of the tenant.
- tenant
Slug string - Slug of the tenant.
- termination
AId number - Id of the termination a.
- termination
AType string - Termination a type to match.
- termination
BId number - Id of the termination b.
- termination
BType string - Termination b type to match.
- type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- unterminated boolean
- Unterminated.
- bundle_
id float - Id of the cable bundle.
- bundle_
name str - Name of the cable bundle.
- circuittermination_
id float - Id of the circuittermination.
- color str
- Color to match.
- consoleport_
id float - Id of the consoleport.
- consoleserverport_
id float - Id of the consoleserverport.
- created str
- custom_
field_ Mapping[str, str]filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description str
- device_
id float - Id of a device the cable is connected to.
- device_
name str - Name of a device the cable is connected to.
- frontport_
id float - Id of the frontport.
- id float
- NetBox id.
- interface_
id float - Id of the interface.
- label str
- Physical label.
- last_
updated str - length float
- Cable length; requires length_unit.
- length_
unit str - Unit of length. One of: km, m, cm, mi, ft, in.
- location_
id float - Id of the location a termination of the cable is in.
- location_
slug str - Slug of the location.
- owner_
group_ floatid - Id of the owner group.
- owner_
group_ strname - Name of the owner group.
- owner_
id float - Id of the owner the object is assigned to.
- owner_
name str - Name of the owner.
- powerfeed_
id float - Id of the powerfeed.
- poweroutlet_
id float - Id of the poweroutlet.
- powerport_
id float - Id of the powerport.
- profile str
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- q str
- Search term, matched against the fields NetBox searches for this object type.
- rack_
id float - Id of the rack a termination of the cable is in.
- rack_
name str - Name of the rack.
- rearport_
id float - Id of the rearport.
- site_
id float - Id of the site a termination of the cable is in.
- site_
slug str - Slug of the site a termination of the cable is in.
- status str
- Cable status. One of: connected, planned, decommissioning.
- tag_
id float - Id of a tag the object carries.
- tag_
slug str - Slug of a tag the object carries.
- tenant_
group_ strid - Id of the tenant group.
- tenant_
group_ strslug - Slug of the tenant group.
- tenant_
id float - Id of the tenant.
- tenant_
slug str - Slug of the tenant.
- termination_
a_ floatid - Id of the termination a.
- termination_
a_ strtype - Termination a type to match.
- termination_
b_ floatid - Id of the termination b.
- termination_
b_ strtype - Termination b type to match.
- type str
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- unterminated bool
- Unterminated.
- bundle
Id Number - Id of the cable bundle.
- bundle
Name String - Name of the cable bundle.
- circuittermination
Id Number - Id of the circuittermination.
- color String
- Color to match.
- consoleport
Id Number - Id of the consoleport.
- consoleserverport
Id Number - Id of the consoleserverport.
- created String
- custom
Field Map<String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description String
- device
Id Number - Id of a device the cable is connected to.
- device
Name String - Name of a device the cable is connected to.
- frontport
Id Number - Id of the frontport.
- id Number
- NetBox id.
- interface
Id Number - Id of the interface.
- label String
- Physical label.
- last
Updated String - length Number
- Cable length; requires length_unit.
- length
Unit String - Unit of length. One of: km, m, cm, mi, ft, in.
- location
Id Number - Id of the location a termination of the cable is in.
- location
Slug String - Slug of the location.
- owner
Group NumberId - Id of the owner group.
- owner
Group StringName - Name of the owner group.
- owner
Id Number - Id of the owner the object is assigned to.
- owner
Name String - Name of the owner.
- powerfeed
Id Number - Id of the powerfeed.
- poweroutlet
Id Number - Id of the poweroutlet.
- powerport
Id Number - Id of the powerport.
- profile String
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- rack
Id Number - Id of the rack a termination of the cable is in.
- rack
Name String - Name of the rack.
- rearport
Id Number - Id of the rearport.
- site
Id Number - Id of the site a termination of the cable is in.
- site
Slug String - Slug of the site a termination of the cable is in.
- status String
- Cable status. One of: connected, planned, decommissioning.
- tag
Id Number - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
- tenant
Group StringId - Id of the tenant group.
- tenant
Group StringSlug - Slug of the tenant group.
- tenant
Id Number - Id of the tenant.
- tenant
Slug String - Slug of the tenant.
- termination
AId Number - Id of the termination a.
- termination
AType String - Termination a type to match.
- termination
BId Number - Id of the termination b.
- termination
BType String - Termination b type to match.
- type String
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- unterminated Boolean
- Unterminated.
getCable Result
The following output properties are available:
- ASide
Get
Cable ASide - What the A side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- BSide
Get
Cable BSide - What the B side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- Bundle
Id double - Id of the cable bundle.
- Color
Hex string - RGB color in hex (e.g. ff0000).
- Comments string
- Created string
- Custom
Fields Dictionary<string, string> - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- Description string
- Id double
- NetBox id.
- Label string
- Physical label.
- Last
Updated string - Length double
- Cable length; requires length_unit.
- Length
Unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- Owner
Id double - Id of the owner the object is assigned to.
- Profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- Status string
- Cable status. One of: connected, planned, decommissioning.
- List<string>
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- List<string>
- Slugs of all tags on the object, including the provider's default_tags.
- Tenant
Id double - Id of the tenant.
- Type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- Url string
- Bundle
Name string - Name of the cable bundle.
- Circuittermination
Id double - Id of the circuittermination.
- Color string
- Color to match.
- Consoleport
Id double - Id of the consoleport.
- Consoleserverport
Id double - Id of the consoleserverport.
- Custom
Field Dictionary<string, string>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Device
Id double - Id of a device the cable is connected to.
- Device
Name string - Name of a device the cable is connected to.
- Frontport
Id double - Id of the frontport.
- Interface
Id double - Id of the interface.
- Location
Id double - Id of the location a termination of the cable is in.
- Location
Slug string - Slug of the location.
- Owner
Group doubleId - Id of the owner group.
- Owner
Group stringName - Name of the owner group.
- Owner
Name string - Name of the owner.
- Powerfeed
Id double - Id of the powerfeed.
- Poweroutlet
Id double - Id of the poweroutlet.
- Powerport
Id double - Id of the powerport.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Rack
Id double - Id of the rack a termination of the cable is in.
- Rack
Name string - Name of the rack.
- Rearport
Id double - Id of the rearport.
- Site
Id double - Id of the site a termination of the cable is in.
- Site
Slug string - Slug of the site a termination of the cable is in.
- Tag
Id double - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- Tenant
Group stringId - Id of the tenant group.
- Tenant
Group stringSlug - Slug of the tenant group.
- Tenant
Slug string - Slug of the tenant.
- Termination
AId double - Id of the termination a.
- Termination
AType string - Termination a type to match.
- Termination
BId double - Id of the termination b.
- Termination
BType string - Termination b type to match.
- Unterminated bool
- Unterminated.
- ASide
Get
Cable ASide - What the A side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- BSide
Get
Cable BSide - What the B side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- Bundle
Id float64 - Id of the cable bundle.
- Color
Hex string - RGB color in hex (e.g. ff0000).
- Comments string
- Created string
- Custom
Fields map[string]string - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- Description string
- Id float64
- NetBox id.
- Label string
- Physical label.
- Last
Updated string - Length float64
- Cable length; requires length_unit.
- Length
Unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- Owner
Id float64 - Id of the owner the object is assigned to.
- Profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- Status string
- Cable status. One of: connected, planned, decommissioning.
- []string
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- []string
- Slugs of all tags on the object, including the provider's default_tags.
- Tenant
Id float64 - Id of the tenant.
- Type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- Url string
- Bundle
Name string - Name of the cable bundle.
- Circuittermination
Id float64 - Id of the circuittermination.
- Color string
- Color to match.
- Consoleport
Id float64 - Id of the consoleport.
- Consoleserverport
Id float64 - Id of the consoleserverport.
- Custom
Field map[string]stringFilters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Device
Id float64 - Id of a device the cable is connected to.
- Device
Name string - Name of a device the cable is connected to.
- Frontport
Id float64 - Id of the frontport.
- Interface
Id float64 - Id of the interface.
- Location
Id float64 - Id of the location a termination of the cable is in.
- Location
Slug string - Slug of the location.
- Owner
Group float64Id - Id of the owner group.
- Owner
Group stringName - Name of the owner group.
- Owner
Name string - Name of the owner.
- Powerfeed
Id float64 - Id of the powerfeed.
- Poweroutlet
Id float64 - Id of the poweroutlet.
- Powerport
Id float64 - Id of the powerport.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Rack
Id float64 - Id of the rack a termination of the cable is in.
- Rack
Name string - Name of the rack.
- Rearport
Id float64 - Id of the rearport.
- Site
Id float64 - Id of the site a termination of the cable is in.
- Site
Slug string - Slug of the site a termination of the cable is in.
- Tag
Id float64 - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- Tenant
Group stringId - Id of the tenant group.
- Tenant
Group stringSlug - Slug of the tenant group.
- Tenant
Slug string - Slug of the tenant.
- Termination
AId float64 - Id of the termination a.
- Termination
AType string - Termination a type to match.
- Termination
BId float64 - Id of the termination b.
- Termination
BType string - Termination b type to match.
- Unterminated bool
- Unterminated.
- a_
side object - What the A side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- b_
side object - What the B side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- bundle_
id number - Id of the cable bundle.
- color_
hex string - RGB color in hex (e.g. ff0000).
- comments string
- created string
- custom_
fields map(string) - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description string
- id number
- NetBox id.
- label string
- Physical label.
- last_
updated string - length number
- Cable length; requires length_unit.
- length_
unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- owner_
id number - Id of the owner the object is assigned to.
- profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- status string
- Cable status. One of: connected, planned, decommissioning.
- list(string)
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- list(string)
- Slugs of all tags on the object, including the provider's default_tags.
- tenant_
id number - Id of the tenant.
- type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- url string
- bundle_
name string - Name of the cable bundle.
- circuittermination_
id number - Id of the circuittermination.
- color string
- Color to match.
- consoleport_
id number - Id of the consoleport.
- consoleserverport_
id number - Id of the consoleserverport.
- custom_
field_ map(string)filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- device_
id number - Id of a device the cable is connected to.
- device_
name string - Name of a device the cable is connected to.
- frontport_
id number - Id of the frontport.
- interface_
id number - Id of the interface.
- location_
id number - Id of the location a termination of the cable is in.
- location_
slug string - Slug of the location.
- owner_
group_ numberid - Id of the owner group.
- owner_
group_ stringname - Name of the owner group.
- owner_
name string - Name of the owner.
- powerfeed_
id number - Id of the powerfeed.
- poweroutlet_
id number - Id of the poweroutlet.
- powerport_
id number - Id of the powerport.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- rack_
id number - Id of the rack a termination of the cable is in.
- rack_
name string - Name of the rack.
- rearport_
id number - Id of the rearport.
- site_
id number - Id of the site a termination of the cable is in.
- site_
slug string - Slug of the site a termination of the cable is in.
- tag_
id number - Id of a tag the object carries.
- tag_
slug string - Slug of a tag the object carries.
- tenant_
group_ stringid - Id of the tenant group.
- tenant_
group_ stringslug - Slug of the tenant group.
- tenant_
slug string - Slug of the tenant.
- termination_
a_ numberid - Id of the termination a.
- termination_
a_ stringtype - Termination a type to match.
- termination_
b_ numberid - Id of the termination b.
- termination_
b_ stringtype - Termination b type to match.
- unterminated bool
- Unterminated.
- a
Side GetCable ASide - What the A side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- b
Side GetCable BSide - What the B side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- bundle
Id Double - Id of the cable bundle.
- color
Hex String - RGB color in hex (e.g. ff0000).
- comments String
- created String
- custom
Fields Map<String,String> - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description String
- id Double
- NetBox id.
- label String
- Physical label.
- last
Updated String - length Double
- Cable length; requires length_unit.
- length
Unit String - Unit of length. One of: km, m, cm, mi, ft, in.
- owner
Id Double - Id of the owner the object is assigned to.
- profile String
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- status String
- Cable status. One of: connected, planned, decommissioning.
- List<String>
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- List<String>
- Slugs of all tags on the object, including the provider's default_tags.
- tenant
Id Double - Id of the tenant.
- type String
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- url String
- bundle
Name String - Name of the cable bundle.
- circuittermination
Id Double - Id of the circuittermination.
- color String
- Color to match.
- consoleport
Id Double - Id of the consoleport.
- consoleserverport
Id Double - Id of the consoleserverport.
- custom
Field Map<String,String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- device
Id Double - Id of a device the cable is connected to.
- device
Name String - Name of a device the cable is connected to.
- frontport
Id Double - Id of the frontport.
- interface
Id Double - Id of the interface.
- location
Id Double - Id of the location a termination of the cable is in.
- location
Slug String - Slug of the location.
- owner
Group DoubleId - Id of the owner group.
- owner
Group StringName - Name of the owner group.
- owner
Name String - Name of the owner.
- powerfeed
Id Double - Id of the powerfeed.
- poweroutlet
Id Double - Id of the poweroutlet.
- powerport
Id Double - Id of the powerport.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- rack
Id Double - Id of the rack a termination of the cable is in.
- rack
Name String - Name of the rack.
- rearport
Id Double - Id of the rearport.
- site
Id Double - Id of the site a termination of the cable is in.
- site
Slug String - Slug of the site a termination of the cable is in.
- tag
Id Double - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
- tenant
Group StringId - Id of the tenant group.
- tenant
Group StringSlug - Slug of the tenant group.
- tenant
Slug String - Slug of the tenant.
- termination
AId Double - Id of the termination a.
- termination
AType String - Termination a type to match.
- termination
BId Double - Id of the termination b.
- termination
BType String - Termination b type to match.
- unterminated Boolean
- Unterminated.
- a
Side GetCable ASide - What the A side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- b
Side GetCable BSide - What the B side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- bundle
Id number - Id of the cable bundle.
- color
Hex string - RGB color in hex (e.g. ff0000).
- comments string
- created string
- custom
Fields {[key: string]: string} - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description string
- id number
- NetBox id.
- label string
- Physical label.
- last
Updated string - length number
- Cable length; requires length_unit.
- length
Unit string - Unit of length. One of: km, m, cm, mi, ft, in.
- owner
Id number - Id of the owner the object is assigned to.
- profile string
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- status string
- Cable status. One of: connected, planned, decommissioning.
- string[]
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- string[]
- Slugs of all tags on the object, including the provider's default_tags.
- tenant
Id number - Id of the tenant.
- type string
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- url string
- bundle
Name string - Name of the cable bundle.
- circuittermination
Id number - Id of the circuittermination.
- color string
- Color to match.
- consoleport
Id number - Id of the consoleport.
- consoleserverport
Id number - Id of the consoleserverport.
- custom
Field {[key: string]: string}Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- device
Id number - Id of a device the cable is connected to.
- device
Name string - Name of a device the cable is connected to.
- frontport
Id number - Id of the frontport.
- interface
Id number - Id of the interface.
- location
Id number - Id of the location a termination of the cable is in.
- location
Slug string - Slug of the location.
- owner
Group numberId - Id of the owner group.
- owner
Group stringName - Name of the owner group.
- owner
Name string - Name of the owner.
- powerfeed
Id number - Id of the powerfeed.
- poweroutlet
Id number - Id of the poweroutlet.
- powerport
Id number - Id of the powerport.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- rack
Id number - Id of the rack a termination of the cable is in.
- rack
Name string - Name of the rack.
- rearport
Id number - Id of the rearport.
- site
Id number - Id of the site a termination of the cable is in.
- site
Slug string - Slug of the site a termination of the cable is in.
- tag
Id number - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- tenant
Group stringId - Id of the tenant group.
- tenant
Group stringSlug - Slug of the tenant group.
- tenant
Slug string - Slug of the tenant.
- termination
AId number - Id of the termination a.
- termination
AType string - Termination a type to match.
- termination
BId number - Id of the termination b.
- termination
BType string - Termination b type to match.
- unterminated boolean
- Unterminated.
- a_
side GetCable ASide - What the A side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- b_
side GetCable BSide - What the B side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- bundle_
id float - Id of the cable bundle.
- color_
hex str - RGB color in hex (e.g. ff0000).
- comments str
- created str
- custom_
fields Mapping[str, str] - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description str
- id float
- NetBox id.
- label str
- Physical label.
- last_
updated str - length float
- Cable length; requires length_unit.
- length_
unit str - Unit of length. One of: km, m, cm, mi, ft, in.
- owner_
id float - Id of the owner the object is assigned to.
- profile str
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- status str
- Cable status. One of: connected, planned, decommissioning.
- Sequence[str]
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- Sequence[str]
- Slugs of all tags on the object, including the provider's default_tags.
- tenant_
id float - Id of the tenant.
- type str
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- url str
- bundle_
name str - Name of the cable bundle.
- circuittermination_
id float - Id of the circuittermination.
- color str
- Color to match.
- consoleport_
id float - Id of the consoleport.
- consoleserverport_
id float - Id of the consoleserverport.
- custom_
field_ Mapping[str, str]filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- device_
id float - Id of a device the cable is connected to.
- device_
name str - Name of a device the cable is connected to.
- frontport_
id float - Id of the frontport.
- interface_
id float - Id of the interface.
- location_
id float - Id of the location a termination of the cable is in.
- location_
slug str - Slug of the location.
- owner_
group_ floatid - Id of the owner group.
- owner_
group_ strname - Name of the owner group.
- owner_
name str - Name of the owner.
- powerfeed_
id float - Id of the powerfeed.
- poweroutlet_
id float - Id of the poweroutlet.
- powerport_
id float - Id of the powerport.
- q str
- Search term, matched against the fields NetBox searches for this object type.
- rack_
id float - Id of the rack a termination of the cable is in.
- rack_
name str - Name of the rack.
- rearport_
id float - Id of the rearport.
- site_
id float - Id of the site a termination of the cable is in.
- site_
slug str - Slug of the site a termination of the cable is in.
- tag_
id float - Id of a tag the object carries.
- tag_
slug str - Slug of a tag the object carries.
- tenant_
group_ strid - Id of the tenant group.
- tenant_
group_ strslug - Slug of the tenant group.
- tenant_
slug str - Slug of the tenant.
- termination_
a_ floatid - Id of the termination a.
- termination_
a_ strtype - Termination a type to match.
- termination_
b_ floatid - Id of the termination b.
- termination_
b_ strtype - Termination b type to match.
- unterminated bool
- Unterminated.
- a
Side Property Map - What the A side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- b
Side Property Map - What the B side terminates on: objects of one type (NetBox's rule), one or several for a breakout, in order (with a profile the position is the connector). Give object*type and ids, or exactly one of the typed **ids lists, which is an alias of the same thing.
- bundle
Id Number - Id of the cable bundle.
- color
Hex String - RGB color in hex (e.g. ff0000).
- comments String
- created String
- custom
Fields Map<String> - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description String
- id Number
- NetBox id.
- label String
- Physical label.
- last
Updated String - length Number
- Cable length; requires length_unit.
- length
Unit String - Unit of length. One of: km, m, cm, mi, ft, in.
- owner
Id Number - Id of the owner the object is assigned to.
- profile String
- Cable profile (connectors and positions per side); with one set, each termination's position in the list is its connector. NetBox rejects clearing it, so unset keeps the current value. One of: single-1c1p, single-1c2p, single-1c4p, single-1c6p, single-1c8p, single-1c12p, single-1c16p, trunk-2c1p, trunk-2c2p, trunk-2c4p, trunk-2c4p-shuffle, trunk-2c6p, trunk-2c8p, trunk-2c12p, trunk-4c1p, trunk-4c2p, trunk-4c4p, trunk-4c4p-shuffle, trunk-4c6p, trunk-4c8p, trunk-8c4p, breakout-1c2p-2c1p, breakout-1c4p-4c1p, breakout-1c6p-6c1p, breakout-1c8p-8c1p, breakout-2c4p-8c1p-shuffle.
- status String
- Cable status. One of: connected, planned, decommissioning.
- List<String>
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- List<String>
- Slugs of all tags on the object, including the provider's default_tags.
- tenant
Id Number - Id of the tenant.
- type String
- Cable type as its NetBox slug, e.g. cat6, smf-os2, power (any of NetBox's cable type choices).
- url String
- bundle
Name String - Name of the cable bundle.
- circuittermination
Id Number - Id of the circuittermination.
- color String
- Color to match.
- consoleport
Id Number - Id of the consoleport.
- consoleserverport
Id Number - Id of the consoleserverport.
- custom
Field Map<String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- device
Id Number - Id of a device the cable is connected to.
- device
Name String - Name of a device the cable is connected to.
- frontport
Id Number - Id of the frontport.
- interface
Id Number - Id of the interface.
- location
Id Number - Id of the location a termination of the cable is in.
- location
Slug String - Slug of the location.
- owner
Group NumberId - Id of the owner group.
- owner
Group StringName - Name of the owner group.
- owner
Name String - Name of the owner.
- powerfeed
Id Number - Id of the powerfeed.
- poweroutlet
Id Number - Id of the poweroutlet.
- powerport
Id Number - Id of the powerport.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- rack
Id Number - Id of the rack a termination of the cable is in.
- rack
Name String - Name of the rack.
- rearport
Id Number - Id of the rearport.
- site
Id Number - Id of the site a termination of the cable is in.
- site
Slug String - Slug of the site a termination of the cable is in.
- tag
Id Number - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
- tenant
Group StringId - Id of the tenant group.
- tenant
Group StringSlug - Slug of the tenant group.
- tenant
Slug String - Slug of the tenant.
- termination
AId Number - Id of the termination a.
- termination
AType String - Termination a type to match.
- termination
BId Number - Id of the termination b.
- termination
BType String - Termination b type to match.
- unterminated Boolean
- Unterminated.
Supporting Types
GetCableASide
- Circuit
Termination List<double>Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- Console
Port List<double>Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- Console
Server List<double>Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- Device
Interface List<double>Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- Front
Port List<double>Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- Ids List<double>
- Ids of the terminating objects, in order (see object_type).
- Object
Type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- Power
Feed List<double>Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- Power
Outlet List<double>Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- Power
Port List<double>Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- Rear
Port List<double>Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- Circuit
Termination []float64Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- Console
Port []float64Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- Console
Server []float64Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- Device
Interface []float64Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- Front
Port []float64Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- Ids []float64
- Ids of the terminating objects, in order (see object_type).
- Object
Type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- Power
Feed []float64Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- Power
Outlet []float64Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- Power
Port []float64Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- Rear
Port []float64Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit_
termination_ list(number)ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console_
port_ list(number)ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console_
server_ list(number)port_ ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device_
interface_ list(number)ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front_
port_ list(number)ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids list(number)
- Ids of the terminating objects, in order (see object_type).
- object_
type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power_
feed_ list(number)ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power_
outlet_ list(number)ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power_
port_ list(number)ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear_
port_ list(number)ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit
Termination List<Double>Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console
Port List<Double>Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console
Server List<Double>Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device
Interface List<Double>Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front
Port List<Double>Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids List<Double>
- Ids of the terminating objects, in order (see object_type).
- object
Type String - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power
Feed List<Double>Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power
Outlet List<Double>Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power
Port List<Double>Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear
Port List<Double>Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit
Termination number[]Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console
Port number[]Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console
Server number[]Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device
Interface number[]Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front
Port number[]Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids number[]
- Ids of the terminating objects, in order (see object_type).
- object
Type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power
Feed number[]Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power
Outlet number[]Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power
Port number[]Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear
Port number[]Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit_
termination_ Sequence[float]ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console_
port_ Sequence[float]ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console_
server_ Sequence[float]port_ ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device_
interface_ Sequence[float]ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front_
port_ Sequence[float]ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids Sequence[float]
- Ids of the terminating objects, in order (see object_type).
- object_
type str - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power_
feed_ Sequence[float]ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power_
outlet_ Sequence[float]ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power_
port_ Sequence[float]ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear_
port_ Sequence[float]ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit
Termination List<Number>Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console
Port List<Number>Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console
Server List<Number>Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device
Interface List<Number>Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front
Port List<Number>Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids List<Number>
- Ids of the terminating objects, in order (see object_type).
- object
Type String - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power
Feed List<Number>Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power
Outlet List<Number>Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power
Port List<Number>Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear
Port List<Number>Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
GetCableBSide
- Circuit
Termination List<double>Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- Console
Port List<double>Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- Console
Server List<double>Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- Device
Interface List<double>Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- Front
Port List<double>Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- Ids List<double>
- Ids of the terminating objects, in order (see object_type).
- Object
Type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- Power
Feed List<double>Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- Power
Outlet List<double>Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- Power
Port List<double>Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- Rear
Port List<double>Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- Circuit
Termination []float64Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- Console
Port []float64Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- Console
Server []float64Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- Device
Interface []float64Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- Front
Port []float64Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- Ids []float64
- Ids of the terminating objects, in order (see object_type).
- Object
Type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- Power
Feed []float64Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- Power
Outlet []float64Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- Power
Port []float64Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- Rear
Port []float64Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit_
termination_ list(number)ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console_
port_ list(number)ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console_
server_ list(number)port_ ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device_
interface_ list(number)ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front_
port_ list(number)ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids list(number)
- Ids of the terminating objects, in order (see object_type).
- object_
type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power_
feed_ list(number)ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power_
outlet_ list(number)ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power_
port_ list(number)ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear_
port_ list(number)ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit
Termination List<Double>Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console
Port List<Double>Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console
Server List<Double>Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device
Interface List<Double>Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front
Port List<Double>Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids List<Double>
- Ids of the terminating objects, in order (see object_type).
- object
Type String - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power
Feed List<Double>Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power
Outlet List<Double>Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power
Port List<Double>Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear
Port List<Double>Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit
Termination number[]Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console
Port number[]Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console
Server number[]Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device
Interface number[]Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front
Port number[]Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids number[]
- Ids of the terminating objects, in order (see object_type).
- object
Type string - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power
Feed number[]Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power
Outlet number[]Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power
Port number[]Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear
Port number[]Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit_
termination_ Sequence[float]ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console_
port_ Sequence[float]ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console_
server_ Sequence[float]port_ ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device_
interface_ Sequence[float]ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front_
port_ Sequence[float]ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids Sequence[float]
- Ids of the terminating objects, in order (see object_type).
- object_
type str - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power_
feed_ Sequence[float]ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power_
outlet_ Sequence[float]ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power_
port_ Sequence[float]ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear_
port_ Sequence[float]ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
- circuit
Termination List<Number>Ids - Ids of the circuit terminations this side terminates on (object*type circuits.circuittermination). Conflicts with the other **ids lists and with object_type/ids.
- console
Port List<Number>Ids - Ids of the console ports this side terminates on (object*type dcim.consoleport). Conflicts with the other **ids lists and with object_type/ids.
- console
Server List<Number>Port Ids - Ids of the console server ports this side terminates on (object*type dcim.consoleserverport). Conflicts with the other **ids lists and with object_type/ids.
- device
Interface List<Number>Ids - Ids of the device interfaces this side terminates on (object*type dcim.interface). Conflicts with the other **ids lists and with object_type/ids.
- front
Port List<Number>Ids - Ids of the front ports this side terminates on (object*type dcim.frontport). Conflicts with the other **ids lists and with object_type/ids.
- ids List<Number>
- Ids of the terminating objects, in order (see object_type).
- object
Type String - Content type of the terminating objects. Derived from the *_ids list that is set; set it together with ids otherwise. One of: dcim.interface, dcim.frontport, dcim.rearport, dcim.consoleport, dcim.consoleserverport, dcim.powerport, dcim.poweroutlet, dcim.powerfeed, circuits.circuittermination.
- power
Feed List<Number>Ids - Ids of the power feeds this side terminates on (object*type dcim.powerfeed). Conflicts with the other **ids lists and with object_type/ids.
- power
Outlet List<Number>Ids - Ids of the power outlets this side terminates on (object*type dcim.poweroutlet). Conflicts with the other **ids lists and with object_type/ids.
- power
Port List<Number>Ids - Ids of the power ports this side terminates on (object*type dcim.powerport). Conflicts with the other **ids lists and with object_type/ids.
- rear
Port List<Number>Ids - Ids of the rear ports this side terminates on (object*type dcim.rearport). Conflicts with the other **ids lists and with object_type/ids.
Package Details
- Repository
- netbox e-breuninger/terraform-provider-netbox
- License
- Notes
- This Pulumi package is based on the
netboxTerraform Provider.
published on Monday, Nov 16, 2026 by e-breuninger