published on Monday, Nov 16, 2026 by e-breuninger
published on Monday, Nov 16, 2026 by e-breuninger
A termination attaching one side of a circuit to a site or provider network (circuits.circuittermination).
From the official documentation:
The association of a circuit with a particular site and/or device is modeled separately as a circuit termination. A circuit may have up to two terminations, labeled A and Z. A single-termination circuit can be used when you don’t know (or care) about the far end of a circuit (for example, an Internet access circuit which connects to a transit provider). A dual-termination circuit is useful for tracking circuits which connect two sites.
Each circuit termination is attached to either a site or to a provider network. Site terminations may optionally be connected via a cable to a specific device interface or port within that site. Each termination must be assigned a port speed, and can optionally be assigned an upstream speed if it differs from the downstream speed (a common scenario with e.g. DOCSIS cable modems). Fields are also available to track cross-connect and patch panel details.
Example Usage
import * as pulumi from "@pulumi/pulumi";
import * as netbox from "@pulumi/netbox";
const test = netbox.getCircuitTermination({
id: 123,
});
import pulumi
import pulumi_netbox as netbox
test = netbox.get_circuit_termination(id=123)
package main
import (
"github.com/pulumi/pulumi-terraform-provider/sdks/go/netbox/v6/netbox"
"github.com/pulumi/pulumi/sdk/v3/go/pulumi"
)
func main() {
pulumi.Run(func(ctx *pulumi.Context) error {
_, err := netbox.LookupCircuitTermination(ctx, &netbox.LookupCircuitTerminationArgs{
Id: pulumi.Float64Ref(123),
}, nil)
if err != nil {
return err
}
return nil
})
}
using System.Collections.Generic;
using System.Linq;
using Pulumi;
using Netbox = Pulumi.Netbox;
return await Deployment.RunAsync(() =>
{
var test = Netbox.GetCircuitTermination.Invoke(new()
{
Id = 123,
});
});
package generated_program;
import com.pulumi.Context;
import com.pulumi.Pulumi;
import com.pulumi.core.Output;
import com.pulumi.netbox.NetboxFunctions;
import com.pulumi.netbox.inputs.GetCircuitTerminationArgs;
import java.util.List;
import java.util.ArrayList;
import java.util.Map;
import java.io.File;
import java.nio.file.Files;
import java.nio.file.Paths;
public class App {
public static void main(String[] args) {
Pulumi.run(App::stack);
}
public static void stack(Context ctx) {
final var test = NetboxFunctions.getCircuitTermination(GetCircuitTerminationArgs.builder()
.id(123)
.build());
}
}
variables:
test:
fn::invoke:
function: netbox:getCircuitTermination
arguments:
id: 123
Example coming soon!
Using getCircuitTermination
Two invocation forms are available. The direct form accepts plain arguments and either blocks until the result value is available, or returns a Promise-wrapped result. The output form accepts Input-wrapped arguments and returns an Output-wrapped result.
function getCircuitTermination(args: GetCircuitTerminationArgs, opts?: InvokeOptions): Promise<GetCircuitTerminationResult>
function getCircuitTerminationOutput(args: GetCircuitTerminationOutputArgs, opts?: InvokeOutputOptions): Output<GetCircuitTerminationResult>def get_circuit_termination(cable_connector: Optional[float] = None,
cable_end: Optional[str] = None,
cable_id: Optional[float] = None,
cabled: Optional[bool] = None,
circuit_id: Optional[float] = None,
created: Optional[str] = None,
custom_field_filters: Optional[Mapping[str, str]] = None,
description: Optional[str] = None,
id: Optional[float] = None,
last_updated: Optional[str] = None,
location_id: Optional[float] = None,
location_slug: Optional[str] = None,
mark_connected: Optional[bool] = None,
occupied: Optional[bool] = None,
port_speed_kbps: Optional[float] = None,
pp_info: Optional[str] = None,
provider_id: Optional[float] = None,
provider_network_id: Optional[float] = None,
provider_slug: Optional[str] = None,
q: Optional[str] = None,
region_id: Optional[float] = None,
region_slug: Optional[str] = None,
site_group_id: Optional[float] = None,
site_group_slug: Optional[str] = None,
site_id: Optional[float] = None,
site_slug: Optional[str] = None,
tag_id: Optional[float] = None,
tag_slug: Optional[str] = None,
term_side: Optional[str] = None,
termination_id: Optional[float] = None,
termination_type: Optional[str] = None,
upstream_speed_kbps: Optional[float] = None,
xconnect_id: Optional[str] = None,
opts: Optional[InvokeOptions] = None) -> GetCircuitTerminationResult
def get_circuit_termination_output(cable_connector: pulumi.Input[Optional[float]] = None,
cable_end: pulumi.Input[Optional[str]] = None,
cable_id: pulumi.Input[Optional[float]] = None,
cabled: pulumi.Input[Optional[bool]] = None,
circuit_id: pulumi.Input[Optional[float]] = None,
created: pulumi.Input[Optional[str]] = None,
custom_field_filters: pulumi.Input[Optional[Mapping[str, pulumi.Input[str]]]] = None,
description: pulumi.Input[Optional[str]] = None,
id: pulumi.Input[Optional[float]] = None,
last_updated: pulumi.Input[Optional[str]] = None,
location_id: pulumi.Input[Optional[float]] = None,
location_slug: pulumi.Input[Optional[str]] = None,
mark_connected: pulumi.Input[Optional[bool]] = None,
occupied: pulumi.Input[Optional[bool]] = None,
port_speed_kbps: pulumi.Input[Optional[float]] = None,
pp_info: pulumi.Input[Optional[str]] = None,
provider_id: pulumi.Input[Optional[float]] = None,
provider_network_id: pulumi.Input[Optional[float]] = None,
provider_slug: pulumi.Input[Optional[str]] = None,
q: pulumi.Input[Optional[str]] = None,
region_id: pulumi.Input[Optional[float]] = None,
region_slug: pulumi.Input[Optional[str]] = None,
site_group_id: pulumi.Input[Optional[float]] = None,
site_group_slug: pulumi.Input[Optional[str]] = None,
site_id: pulumi.Input[Optional[float]] = None,
site_slug: pulumi.Input[Optional[str]] = None,
tag_id: pulumi.Input[Optional[float]] = None,
tag_slug: pulumi.Input[Optional[str]] = None,
term_side: pulumi.Input[Optional[str]] = None,
termination_id: pulumi.Input[Optional[float]] = None,
termination_type: pulumi.Input[Optional[str]] = None,
upstream_speed_kbps: pulumi.Input[Optional[float]] = None,
xconnect_id: pulumi.Input[Optional[str]] = None,
opts: Optional[InvokeOutputOptions] = None) -> Output[GetCircuitTerminationResult]func LookupCircuitTermination(ctx *Context, args *LookupCircuitTerminationArgs, opts ...InvokeOption) (*LookupCircuitTerminationResult, error)
func LookupCircuitTerminationOutput(ctx *Context, args *LookupCircuitTerminationOutputArgs, opts ...InvokeOption) LookupCircuitTerminationResultOutput> Note: This function is named LookupCircuitTermination in the Go SDK.
public static class GetCircuitTermination
{
public static Task<GetCircuitTerminationResult> InvokeAsync(GetCircuitTerminationArgs args, InvokeOptions? opts = null)
public static Output<GetCircuitTerminationResult> Invoke(GetCircuitTerminationInvokeArgs args, InvokeOptions? opts = null)
public static Output<GetCircuitTerminationResult> Invoke(GetCircuitTerminationInvokeArgs args, InvokeOutputOptions opts)
}public static CompletableFuture<GetCircuitTerminationResult> getCircuitTermination(GetCircuitTerminationArgs args, InvokeOptions options)
public static Output<GetCircuitTerminationResult> getCircuitTermination(GetCircuitTerminationArgs args, InvokeOptions options)
public static Output<GetCircuitTerminationResult> getCircuitTermination(GetCircuitTerminationArgs args, InvokeOutputOptions options)
fn::invoke:
function: netbox:index/getCircuitTermination:getCircuitTermination
arguments:
# arguments dictionarydata "netbox_get_circuit_termination" "name" {
# arguments
}The following arguments are supported:
- Cable
Connector double - Cable connector to match.
- Cable
End string - Cable end. One of: A, B.
- Cable
Id double - Id of the cable.
- Cabled bool
- Whether cabled is set.
- Circuit
Id double - Id of the circuit.
- Created string
- Custom
Field Dictionary<string, string>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Description string
- Id double
- NetBox id.
- Last
Updated string - Location
Id double - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- Location
Slug string - Slug of the location.
- Mark
Connected bool - Treat the termination as connected even without a cable.
- Occupied bool
- Whether occupied is set.
- Port
Speed doubleKbps - Physical circuit speed in kbps. Must be a whole number.
- Pp
Info string - Patch panel and port information.
- Provider
Id double - Id of the provider.
- Provider
Network doubleId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- Provider
Slug string - Slug of the provider.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Region
Id double - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- Region
Slug string - Slug of the region.
- Site
Group doubleId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Group stringSlug - Slug of the site group.
- Site
Id double - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Slug string - Slug of the site.
- Tag
Id double - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- Term
Side string - Side of the circuit this terminates. One of: A, Z.
- Termination
Id double - Id of the terminating object (see termination_type).
- Termination
Type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- Upstream
Speed doubleKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- Xconnect
Id string - Cross-connect id assigned by the provider.
- Cable
Connector float64 - Cable connector to match.
- Cable
End string - Cable end. One of: A, B.
- Cable
Id float64 - Id of the cable.
- Cabled bool
- Whether cabled is set.
- Circuit
Id float64 - Id of the circuit.
- Created string
- Custom
Field map[string]stringFilters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Description string
- Id float64
- NetBox id.
- Last
Updated string - Location
Id float64 - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- Location
Slug string - Slug of the location.
- Mark
Connected bool - Treat the termination as connected even without a cable.
- Occupied bool
- Whether occupied is set.
- Port
Speed float64Kbps - Physical circuit speed in kbps. Must be a whole number.
- Pp
Info string - Patch panel and port information.
- Provider
Id float64 - Id of the provider.
- Provider
Network float64Id - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- Provider
Slug string - Slug of the provider.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Region
Id float64 - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- Region
Slug string - Slug of the region.
- Site
Group float64Id - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Group stringSlug - Slug of the site group.
- Site
Id float64 - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Slug string - Slug of the site.
- Tag
Id float64 - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- Term
Side string - Side of the circuit this terminates. One of: A, Z.
- Termination
Id float64 - Id of the terminating object (see termination_type).
- Termination
Type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- Upstream
Speed float64Kbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- Xconnect
Id string - Cross-connect id assigned by the provider.
- cable_
connector number - Cable connector to match.
- cable_
end string - Cable end. One of: A, B.
- cable_
id number - Id of the cable.
- cabled bool
- Whether cabled is set.
- circuit_
id number - Id of the circuit.
- created string
- custom_
field_ map(string)filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description string
- id number
- NetBox id.
- last_
updated string - location_
id number - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- location_
slug string - Slug of the location.
- mark_
connected bool - Treat the termination as connected even without a cable.
- occupied bool
- Whether occupied is set.
- port_
speed_ numberkbps - Physical circuit speed in kbps. Must be a whole number.
- pp_
info string - Patch panel and port information.
- provider_
id number - Id of the provider.
- provider_
network_ numberid - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- provider_
slug string - Slug of the provider.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- region_
id number - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- region_
slug string - Slug of the region.
- site_
group_ numberid - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
group_ stringslug - Slug of the site group.
- site_
id number - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
slug string - Slug of the site.
- tag_
id number - Id of a tag the object carries.
- tag_
slug string - Slug of a tag the object carries.
- term_
side string - Side of the circuit this terminates. One of: A, Z.
- termination_
id number - Id of the terminating object (see termination_type).
- termination_
type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream_
speed_ numberkbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- xconnect_
id string - Cross-connect id assigned by the provider.
- cable
Connector Double - Cable connector to match.
- cable
End String - Cable end. One of: A, B.
- cable
Id Double - Id of the cable.
- cabled Boolean
- Whether cabled is set.
- circuit
Id Double - Id of the circuit.
- created String
- custom
Field Map<String,String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description String
- id Double
- NetBox id.
- last
Updated String - location
Id Double - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- location
Slug String - Slug of the location.
- mark
Connected Boolean - Treat the termination as connected even without a cable.
- occupied Boolean
- Whether occupied is set.
- port
Speed DoubleKbps - Physical circuit speed in kbps. Must be a whole number.
- pp
Info String - Patch panel and port information.
- provider
Id Double - Id of the provider.
- provider
Network DoubleId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- provider
Slug String - Slug of the provider.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- region
Id Double - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- region
Slug String - Slug of the region.
- site
Group DoubleId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Group StringSlug - Slug of the site group.
- site
Id Double - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Slug String - Slug of the site.
- tag
Id Double - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
- term
Side String - Side of the circuit this terminates. One of: A, Z.
- termination
Id Double - Id of the terminating object (see termination_type).
- termination
Type String - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream
Speed DoubleKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- xconnect
Id String - Cross-connect id assigned by the provider.
- cable
Connector number - Cable connector to match.
- cable
End string - Cable end. One of: A, B.
- cable
Id number - Id of the cable.
- cabled boolean
- Whether cabled is set.
- circuit
Id number - Id of the circuit.
- created string
- custom
Field {[key: string]: string}Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description string
- id number
- NetBox id.
- last
Updated string - location
Id number - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- location
Slug string - Slug of the location.
- mark
Connected boolean - Treat the termination as connected even without a cable.
- occupied boolean
- Whether occupied is set.
- port
Speed numberKbps - Physical circuit speed in kbps. Must be a whole number.
- pp
Info string - Patch panel and port information.
- provider
Id number - Id of the provider.
- provider
Network numberId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- provider
Slug string - Slug of the provider.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- region
Id number - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- region
Slug string - Slug of the region.
- site
Group numberId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Group stringSlug - Slug of the site group.
- site
Id number - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Slug string - Slug of the site.
- tag
Id number - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- term
Side string - Side of the circuit this terminates. One of: A, Z.
- termination
Id number - Id of the terminating object (see termination_type).
- termination
Type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream
Speed numberKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- xconnect
Id string - Cross-connect id assigned by the provider.
- cable_
connector float - Cable connector to match.
- cable_
end str - Cable end. One of: A, B.
- cable_
id float - Id of the cable.
- cabled bool
- Whether cabled is set.
- circuit_
id float - Id of the circuit.
- created str
- custom_
field_ Mapping[str, str]filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description str
- id float
- NetBox id.
- last_
updated str - location_
id float - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- location_
slug str - Slug of the location.
- mark_
connected bool - Treat the termination as connected even without a cable.
- occupied bool
- Whether occupied is set.
- port_
speed_ floatkbps - Physical circuit speed in kbps. Must be a whole number.
- pp_
info str - Patch panel and port information.
- provider_
id float - Id of the provider.
- provider_
network_ floatid - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- provider_
slug str - Slug of the provider.
- q str
- Search term, matched against the fields NetBox searches for this object type.
- region_
id float - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- region_
slug str - Slug of the region.
- site_
group_ floatid - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
group_ strslug - Slug of the site group.
- site_
id float - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
slug str - Slug of the site.
- tag_
id float - Id of a tag the object carries.
- tag_
slug str - Slug of a tag the object carries.
- term_
side str - Side of the circuit this terminates. One of: A, Z.
- termination_
id float - Id of the terminating object (see termination_type).
- termination_
type str - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream_
speed_ floatkbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- xconnect_
id str - Cross-connect id assigned by the provider.
- cable
Connector Number - Cable connector to match.
- cable
End String - Cable end. One of: A, B.
- cable
Id Number - Id of the cable.
- cabled Boolean
- Whether cabled is set.
- circuit
Id Number - Id of the circuit.
- created String
- custom
Field Map<String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- description String
- id Number
- NetBox id.
- last
Updated String - location
Id Number - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- location
Slug String - Slug of the location.
- mark
Connected Boolean - Treat the termination as connected even without a cable.
- occupied Boolean
- Whether occupied is set.
- port
Speed NumberKbps - Physical circuit speed in kbps. Must be a whole number.
- pp
Info String - Patch panel and port information.
- provider
Id Number - Id of the provider.
- provider
Network NumberId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- provider
Slug String - Slug of the provider.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- region
Id Number - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- region
Slug String - Slug of the region.
- site
Group NumberId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Group StringSlug - Slug of the site group.
- site
Id Number - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Slug String - Slug of the site.
- tag
Id Number - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
- term
Side String - Side of the circuit this terminates. One of: A, Z.
- termination
Id Number - Id of the terminating object (see termination_type).
- termination
Type String - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream
Speed NumberKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- xconnect
Id String - Cross-connect id assigned by the provider.
getCircuitTermination Result
The following output properties are available:
- Circuit
Id double - Id of the circuit.
- Created string
- Custom
Fields Dictionary<string, string> - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- Description string
- Id double
- NetBox id.
- Last
Updated string - Location
Id double - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- Mark
Connected bool - Treat the termination as connected even without a cable.
- Port
Speed double - Deprecated alias of portspeedkbps.
- Port
Speed doubleKbps - Physical circuit speed in kbps. Must be a whole number.
- Pp
Info string - Patch panel and port information.
- Provider
Network doubleId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- Region
Id double - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Group doubleId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Id double - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- List<string>
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- List<string>
- Slugs of all tags on the object, including the provider's default_tags.
- Term
Side string - Side of the circuit this terminates. One of: A, Z.
- Termination
Id double - Id of the terminating object (see termination_type).
- Termination
Type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- Upstream
Speed double - Deprecated alias of upstreamspeedkbps.
- Upstream
Speed doubleKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- Url string
- Xconnect
Id string - Cross-connect id assigned by the provider.
- Cable
Connector double - Cable connector to match.
- Cable
End string - Cable end. One of: A, B.
- Cable
Id double - Id of the cable.
- Cabled bool
- Whether cabled is set.
- Custom
Field Dictionary<string, string>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Location
Slug string - Slug of the location.
- Occupied bool
- Whether occupied is set.
- Provider
Id double - Id of the provider.
- Provider
Slug string - Slug of the provider.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Region
Slug string - Slug of the region.
- Site
Group stringSlug - Slug of the site group.
- Site
Slug string - Slug of the site.
- Tag
Id double - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- Circuit
Id float64 - Id of the circuit.
- Created string
- Custom
Fields map[string]string - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- Description string
- Id float64
- NetBox id.
- Last
Updated string - Location
Id float64 - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- Mark
Connected bool - Treat the termination as connected even without a cable.
- Port
Speed float64 - Deprecated alias of portspeedkbps.
- Port
Speed float64Kbps - Physical circuit speed in kbps. Must be a whole number.
- Pp
Info string - Patch panel and port information.
- Provider
Network float64Id - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- Region
Id float64 - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Group float64Id - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- Site
Id float64 - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- []string
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- []string
- Slugs of all tags on the object, including the provider's default_tags.
- Term
Side string - Side of the circuit this terminates. One of: A, Z.
- Termination
Id float64 - Id of the terminating object (see termination_type).
- Termination
Type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- Upstream
Speed float64 - Deprecated alias of upstreamspeedkbps.
- Upstream
Speed float64Kbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- Url string
- Xconnect
Id string - Cross-connect id assigned by the provider.
- Cable
Connector float64 - Cable connector to match.
- Cable
End string - Cable end. One of: A, B.
- Cable
Id float64 - Id of the cable.
- Cabled bool
- Whether cabled is set.
- Custom
Field map[string]stringFilters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- Location
Slug string - Slug of the location.
- Occupied bool
- Whether occupied is set.
- Provider
Id float64 - Id of the provider.
- Provider
Slug string - Slug of the provider.
- Q string
- Search term, matched against the fields NetBox searches for this object type.
- Region
Slug string - Slug of the region.
- Site
Group stringSlug - Slug of the site group.
- Site
Slug string - Slug of the site.
- Tag
Id float64 - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- circuit_
id number - Id of the circuit.
- created string
- custom_
fields map(string) - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description string
- id number
- NetBox id.
- last_
updated string - location_
id number - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- mark_
connected bool - Treat the termination as connected even without a cable.
- port_
speed number - Deprecated alias of portspeedkbps.
- port_
speed_ numberkbps - Physical circuit speed in kbps. Must be a whole number.
- pp_
info string - Patch panel and port information.
- provider_
network_ numberid - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- region_
id number - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
group_ numberid - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
id number - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- list(string)
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- list(string)
- Slugs of all tags on the object, including the provider's default_tags.
- term_
side string - Side of the circuit this terminates. One of: A, Z.
- termination_
id number - Id of the terminating object (see termination_type).
- termination_
type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream_
speed number - Deprecated alias of upstreamspeedkbps.
- upstream_
speed_ numberkbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- url string
- xconnect_
id string - Cross-connect id assigned by the provider.
- cable_
connector number - Cable connector to match.
- cable_
end string - Cable end. One of: A, B.
- cable_
id number - Id of the cable.
- cabled bool
- Whether cabled is set.
- custom_
field_ map(string)filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- location_
slug string - Slug of the location.
- occupied bool
- Whether occupied is set.
- provider_
id number - Id of the provider.
- provider_
slug string - Slug of the provider.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- region_
slug string - Slug of the region.
- site_
group_ stringslug - Slug of the site group.
- site_
slug string - Slug of the site.
- tag_
id number - Id of a tag the object carries.
- tag_
slug string - Slug of a tag the object carries.
- circuit
Id Double - Id of the circuit.
- created String
- custom
Fields Map<String,String> - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description String
- id Double
- NetBox id.
- last
Updated String - location
Id Double - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- mark
Connected Boolean - Treat the termination as connected even without a cable.
- port
Speed Double - Deprecated alias of portspeedkbps.
- port
Speed DoubleKbps - Physical circuit speed in kbps. Must be a whole number.
- pp
Info String - Patch panel and port information.
- provider
Network DoubleId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- region
Id Double - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Group DoubleId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Id Double - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- List<String>
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- List<String>
- Slugs of all tags on the object, including the provider's default_tags.
- term
Side String - Side of the circuit this terminates. One of: A, Z.
- termination
Id Double - Id of the terminating object (see termination_type).
- termination
Type String - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream
Speed Double - Deprecated alias of upstreamspeedkbps.
- upstream
Speed DoubleKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- url String
- xconnect
Id String - Cross-connect id assigned by the provider.
- cable
Connector Double - Cable connector to match.
- cable
End String - Cable end. One of: A, B.
- cable
Id Double - Id of the cable.
- cabled Boolean
- Whether cabled is set.
- custom
Field Map<String,String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- location
Slug String - Slug of the location.
- occupied Boolean
- Whether occupied is set.
- provider
Id Double - Id of the provider.
- provider
Slug String - Slug of the provider.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- region
Slug String - Slug of the region.
- site
Group StringSlug - Slug of the site group.
- site
Slug String - Slug of the site.
- tag
Id Double - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
- circuit
Id number - Id of the circuit.
- created string
- custom
Fields {[key: string]: string} - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description string
- id number
- NetBox id.
- last
Updated string - location
Id number - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- mark
Connected boolean - Treat the termination as connected even without a cable.
- port
Speed number - Deprecated alias of portspeedkbps.
- port
Speed numberKbps - Physical circuit speed in kbps. Must be a whole number.
- pp
Info string - Patch panel and port information.
- provider
Network numberId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- region
Id number - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Group numberId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Id number - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- string[]
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- string[]
- Slugs of all tags on the object, including the provider's default_tags.
- term
Side string - Side of the circuit this terminates. One of: A, Z.
- termination
Id number - Id of the terminating object (see termination_type).
- termination
Type string - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream
Speed number - Deprecated alias of upstreamspeedkbps.
- upstream
Speed numberKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- url string
- xconnect
Id string - Cross-connect id assigned by the provider.
- cable
Connector number - Cable connector to match.
- cable
End string - Cable end. One of: A, B.
- cable
Id number - Id of the cable.
- cabled boolean
- Whether cabled is set.
- custom
Field {[key: string]: string}Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- location
Slug string - Slug of the location.
- occupied boolean
- Whether occupied is set.
- provider
Id number - Id of the provider.
- provider
Slug string - Slug of the provider.
- q string
- Search term, matched against the fields NetBox searches for this object type.
- region
Slug string - Slug of the region.
- site
Group stringSlug - Slug of the site group.
- site
Slug string - Slug of the site.
- tag
Id number - Id of a tag the object carries.
- string
- Slug of a tag the object carries.
- circuit_
id float - Id of the circuit.
- created str
- custom_
fields Mapping[str, str] - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description str
- id float
- NetBox id.
- last_
updated str - location_
id float - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- mark_
connected bool - Treat the termination as connected even without a cable.
- port_
speed float - Deprecated alias of portspeedkbps.
- port_
speed_ floatkbps - Physical circuit speed in kbps. Must be a whole number.
- pp_
info str - Patch panel and port information.
- provider_
network_ floatid - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- region_
id float - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
group_ floatid - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site_
id float - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- Sequence[str]
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- Sequence[str]
- Slugs of all tags on the object, including the provider's default_tags.
- term_
side str - Side of the circuit this terminates. One of: A, Z.
- termination_
id float - Id of the terminating object (see termination_type).
- termination_
type str - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream_
speed float - Deprecated alias of upstreamspeedkbps.
- upstream_
speed_ floatkbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- url str
- xconnect_
id str - Cross-connect id assigned by the provider.
- cable_
connector float - Cable connector to match.
- cable_
end str - Cable end. One of: A, B.
- cable_
id float - Id of the cable.
- cabled bool
- Whether cabled is set.
- custom_
field_ Mapping[str, str]filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- location_
slug str - Slug of the location.
- occupied bool
- Whether occupied is set.
- provider_
id float - Id of the provider.
- provider_
slug str - Slug of the provider.
- q str
- Search term, matched against the fields NetBox searches for this object type.
- region_
slug str - Slug of the region.
- site_
group_ strslug - Slug of the site group.
- site_
slug str - Slug of the site.
- tag_
id float - Id of a tag the object carries.
- tag_
slug str - Slug of a tag the object carries.
- circuit
Id Number - Id of the circuit.
- created String
- custom
Fields Map<String> - Custom field values by field name. Every value is a string; NetBox coerces numbers and booleans. An object field holds the related object's id, e.g. "12", a multiobject field a JSON list of ids in any order, e.g. jsonencode([12, 13]). A key removed from the map is cleared in NetBox (set {} to clear all).
- description String
- id Number
- NetBox id.
- last
Updated String - location
Id Number - Id of the terminating location (termination*type dcim.location). Conflicts with the other aliases and with setting the termination** pair directly.
- mark
Connected Boolean - Treat the termination as connected even without a cable.
- port
Speed Number - Deprecated alias of portspeedkbps.
- port
Speed NumberKbps - Physical circuit speed in kbps. Must be a whole number.
- pp
Info String - Patch panel and port information.
- provider
Network NumberId - Id of the terminating provider network (termination*type circuits.providernetwork). Conflicts with the other aliases and with setting the termination** pair directly.
- region
Id Number - Id of the terminating region (termination*type dcim.region). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Group NumberId - Id of the terminating site group (termination*type dcim.sitegroup). Conflicts with the other aliases and with setting the termination** pair directly.
- site
Id Number - Id of the terminating site (termination*type dcim.site). Conflicts with the other aliases and with setting the termination** pair directly.
- List<String>
- Slugs of the tags assigned to the object (the provider's defaulttags are added on top, see tagsall).
- List<String>
- Slugs of all tags on the object, including the provider's default_tags.
- term
Side String - Side of the circuit this terminates. One of: A, Z.
- termination
Id Number - Id of the terminating object (see termination_type).
- termination
Type String - Content type of the termination. Derived from siteid, locationid, regionid, sitegroupid or providernetworkid when one of those is set; set it together with terminationid otherwise. One termination is required. One of: dcim.site, dcim.location, dcim.region, dcim.sitegroup, circuits.providernetwork.
- upstream
Speed Number - Deprecated alias of upstreamspeedkbps.
- upstream
Speed NumberKbps - Upstream speed in kbps if different from the port speed. Must be a whole number.
- url String
- xconnect
Id String - Cross-connect id assigned by the provider.
- cable
Connector Number - Cable connector to match.
- cable
End String - Cable end. One of: A, B.
- cable
Id Number - Id of the cable.
- cabled Boolean
- Whether cabled is set.
- custom
Field Map<String>Filters - Custom field values to match, by field name, e.g. { tier = "gold" }: each entry filters as cf_\n\n with the field's own filter logic, loose (case-insensitive substring) or exact.
- location
Slug String - Slug of the location.
- occupied Boolean
- Whether occupied is set.
- provider
Id Number - Id of the provider.
- provider
Slug String - Slug of the provider.
- q String
- Search term, matched against the fields NetBox searches for this object type.
- region
Slug String - Slug of the region.
- site
Group StringSlug - Slug of the site group.
- site
Slug String - Slug of the site.
- tag
Id Number - Id of a tag the object carries.
- String
- Slug of a tag the object carries.
Package Details
- Repository
- netbox e-breuninger/terraform-provider-netbox
- License
- Notes
- This Pulumi package is based on the
netboxTerraform Provider.
published on Monday, Nov 16, 2026 by e-breuninger